TBC Series Controller

Overview

  • Control Mode: Auto-PID / Manual
  • Control Output: PWM or SSR
  • Consumed Power: < 2.5W
  • Load Capacity: 20A, 50W~2200W(110V) 100W~4400W(220V)
  • Working Humidity: 10~80%RH(No condensing)
  • Power Supply: AC85~ 415V, 50/60HZ
  • Sensor Type: Thermocouple J or K
  • Output Type: Zero Cross / Phase Angle
  • Working Temperature: 0~50℃(32~122℉)
  • Storage Temperature: -20~70℃(-4~158℉)
  • Wide power supply range: 65-415Vac
  • Multiple self-diagnostic: * thermocouple/heater inverse * thermocouple/heater misconnection * fuse broken down * ambient temperature monitor
  • Selectable manual control mode
  • Optional remote standby/alarm output
  • Compatible with YUDO, Athena, DME, PCS, INCOE, etc Cards
  • Flexible configuration: Controlling zones: 1-120 zones
  • Dual lines LED display
  • Advanced PID control algorithm
  • Single zone 15A 3600W
  • Cabinet zone: 1-24

Functions

  • Dehumidify soft start function
  • High/Low temperature alarm
  • Heater open, short, overload alarm
  • Fuse break alarm
  • Over voltage protection function
  • Remote standby function (optional)
  • Availability of frames for 2, 4, 6, 8, 10, 12, 24 zones to select.
  • Thermocouple input protection, prevent module damaged by mis-connection
  • Thermocouple & heater inverse protection, prevent thermocouple damaged by mis-connection
  • Soft-start mode, avoid the humidity make the heater burn out

Technical Specifications

Power Supply

1-phase 3-wire, 240Vac, 50/60Hz

Module Qt'y
1 -> 24
3-phase 4-wire, 240Vac, 50/60Hz
3-phase 5-wire, 380Vac, 50/60Hz
Control Mode
Auto-PID / Manual
Sensor Type
Thermocouple J or K
Temperature Control
0~450℃(32~842℉)
Control Accuracy
±0.1%F.S
Output Type
Zero Cross / Phase Angle
Connector Type
Customized
Load Capacity
15A, 3600W
Wiring Mode
Customized
Storage Temperature
-20~70℃(-4~158℉)
Working Temperature
0~55℃(32~131℉)
Working Humidity
10~80%RH(No condensing)

Alarm turns on when the following occurred:

  • Ultra-high or ultra-low Temperature
  • Thermocouple break, short or inverse
  • Thermocouple is out of its position
  • Heater break, short or overload
  • Output device is damaged
  • Over voltage of power supply

Protection activated in the following situations:

  • Over voltage self-protected, max.AC500V
  • Thermocouple input protection, prevent module damaged by misconnection
  • Thermocouple & heater inverse protection, prevent thermocouple damaged by misconnection
  • Soft-start mode, avoid the moisture make the heater burn out
  • Heater dehumidified time can be extended