TBC Series Controller
Overview
- Control Mode: Auto-PID / Manual
- Control Output: PWM or SSR
- Consumed Power: < 2.5W
- Load Capacity: 20A, 50W~2200W(110V) 100W~4400W(220V)
- Working Humidity: 10~80%RH(No condensing)
- Power Supply: AC85~ 415V, 50/60HZ
- Sensor Type: Thermocouple J or K
- Output Type: Zero Cross / Phase Angle
- Working Temperature: 0~50℃(32~122℉)
- Storage Temperature: -20~70℃(-4~158℉)
- Wide power supply range: 65-415Vac
- Multiple self-diagnostic: * thermocouple/heater inverse * thermocouple/heater misconnection * fuse broken down * ambient temperature monitor
- Selectable manual control mode
- Optional remote standby/alarm output
- Compatible with YUDO, Athena, DME, PCS, INCOE, etc Cards
- Flexible configuration: Controlling zones: 1-120 zones
- Dual lines LED display
- Advanced PID control algorithm
- Single zone 15A 3600W
- Cabinet zone: 1-24
Functions
- Dehumidify soft start function
- High/Low temperature alarm
- Heater open, short, overload alarm
- Fuse break alarm
- Over voltage protection function
- Remote standby function (optional)
- Availability of frames for 2, 4, 6, 8, 10, 12, 24 zones to select.
- Thermocouple input protection, prevent module damaged by mis-connection
- Thermocouple & heater inverse protection, prevent thermocouple damaged by mis-connection
- Soft-start mode, avoid the humidity make the heater burn out
Technical Specifications
Power Supply
|
1-phase 3-wire, 240Vac, 50/60Hz |
Module Qt'y
|
1 -> 24
|
3-phase 4-wire, 240Vac, 50/60Hz | |||
3-phase 5-wire, 380Vac, 50/60Hz
|
Control Mode
|
Auto-PID / Manual
|
|
Sensor Type
|
Thermocouple J or K
|
||
Temperature Control
|
0~450℃(32~842℉)
|
Control Accuracy
|
±0.1%F.S
|
Output Type
|
Zero Cross / Phase Angle
|
||
Connector Type
|
Customized
|
Load Capacity
|
15A, 3600W
|
Wiring Mode
|
Customized
|
Storage Temperature
|
-20~70℃(-4~158℉)
|
Working Temperature
|
0~55℃(32~131℉)
|
Working Humidity
|
10~80%RH(No condensing)
|
Alarm turns on when the following occurred:
- Ultra-high or ultra-low Temperature
- Thermocouple break, short or inverse
- Thermocouple is out of its position
- Heater break, short or overload
- Output device is damaged
- Over voltage of power supply
Protection activated in the following situations:
- Over voltage self-protected, max.AC500V
- Thermocouple input protection, prevent module damaged by misconnection
- Thermocouple & heater inverse protection, prevent thermocouple damaged by misconnection
- Soft-start mode, avoid the moisture make the heater burn out
- Heater dehumidified time can be extended