TFC Series Controller
Overview
Control Mode: Auto-PID / Manual
Control Output: PWM or SSR
Consumed Power: < 2.5W
Load Capacity: 20A, 50W~2200W(110V) 100W~4400W(220V)
Power Supply: AC85~ 400V, 50/60HZ
Sensor Type: Thermocouple J or K
Output Type: Zero Cross / Phase Angle
Working Temperature: 0~50℃(32~122℉)
Storage Temperature: -20~70℃(-4~158℉)
- 1 module card controls 2 temperature zones
- Wide power supply range, AC85~400V
- Thermocouple input protection, prevent module damaged by mis-connection
- Thermocouple & heater inverse protection, prevent thermocouple damaged by mis-connection
- Soft-start mode, avoid the humidity make the heater burn out
Functions
- Auto or manual function
- Internal alarm buzzer
- One card with 2 zones design
- Cabinet Zone – 2->48
- Operate and set parameters separately
- Dehumidify soft start function (avoid the humidity make the heater burn out)
- High/Low temperature alarm
- Thermocouple open, reverse, short alarm
- Heater open, short, overload alarm
- Over voltage protection function
- Thermocouple & heater misconnection protection
- Compatible with YUDO, Athena, DME, PCS, INCOE, etc.
Technical Specifications
Power Supply | 1-phase 3-wire, 240Vac, 50/60Hz | Control Mode | Auto-PID / Manual |
3-phase 4-wire, 240Vac, 50/60Hz | Control Accuracy | ±0.1%F.S | |
3-phase 5-wire, 380Vac, 50/60Hz
|
Load Capacity | 15A, 3600W | |
Sensor Type | Thermocouple J or K | Storage Temperature | -20~70℃(-4~158℉) |
Temperature Control | 0~450℃(32~842℉) | ||
Output Type | Zero Cross / Phase Angle | Working Humidity | 10~80%RH(No condensing) |
Working Temperature | 0~55℃(32~131℉) |
Alarm turns on when the followings occurred
- Ultra-high or ultra-low Temperature
- Thermocouple break, short or inverse
- Thermocouple is out of its position
- Heater break, short or overload
- Output device is damaged
- Over voltage of power supply
Protection activated in the following situations
- Over voltage self-protected, max.AC500V
- Thermocouple input protection, prevent module damaged by misconnection
- Thermocouple & heater inverse protection, prevent thermocouple damaged by misconnection
- Soft-start mode, avoid the moisture make the heater burn out
- Heater dehumidified time can be extended