TNC Series Controller

Overview

Control Mode: Auto-PID / Manual

Control Output: PWM or SSR

Consumed Power: < 2.5W

Load Capacity: 20A, 50W~2200W(110V) 100W~4400W(220V)

Power Supply: AC85~ 400V, 50/60HZ

Sensor Type: Thermocouple J or K

Output Type: Zero Cross / Phase Angle

Working Temperature: 0~50℃(32~122℉)

Storage Temperature: -20~70℃(-4~158℉)

  • Wide power supply range, AC85~400V
  • Thermocouple input protection, prevent module damaged by mis-connection
  • Thermocouple & heater inverse protection, prevent thermocouple damaged by mis-connection
  • Soft-start mode, avoid the humidity make the heater burn out

Functions

  • Internal alarm buzzer
  • 1-24 zone selectable
  • Compatible with DME, Athena, Yudo, etc. cards
  • One key start-stop, boost function
  • Soft start function
  • Triac short circuit protection
  • Automatic detection of wire break of heater
  • Auto or manual function
  • Boost function
  • High/Low temperature alarm
  • Thermocouple open, reverse, short alarm
  • Heater open, short, overload alarm
  • Over voltage protection function
  • Thermocouple & heater misconnection protection

Technical Specifications

Power Supply 1-phase 3-wire, 240Vac, 50/60Hz Control Mode Auto-PID / Manual
3-phase 4-wire, 240Vac, 50/60Hz Control Accuracy ±0.1%F.S
3-phase 5-wire, 380Vac, 50/60Hz Load Capacity 15A, 3600W
Sensor Type Thermocouple J or K Storage Temperature -20~70℃(-4~158℉)
Temperature Control 0~450℃(32~842℉)
Output Type Zero Cross / Phase Angle Working Humidity 10~80%RH(No condensing)
Working Temperature 0~55℃(32~131℉)
 

Alarm turns on when the followings occurred

  • Ultra-high or ultra-low Temperature
  • Thermocouple break, short or inverse
  • Thermocouple is out of its position
  • Heater break, short or overload
  • Output device is damaged
  • Over voltage of power supply

Meet us at The World's No. 1 Trade Fair for Plastics and Rubber